Model:JXFSTPRP-GXC
Brand:Shanghai Jingxin
Specifications :Set
Introduction:Grinding biological samples at low temperature can effectively inhibit nucleic acid degradation, retain protein activity, and process samples in large quantities.
Product Description:
JXFSTPRP-GXC® cryogenic tissue grinder (patented product, counterfeiting must be punished! ZL2017305264903) of Shanghai Jingxin® is a special, fast, high-efficiency, multi-test tube consistent system. It can extract and purify the original DNA, RNA and protein from any source (including soil, plant and animal tissues/organs, bacteria, yeast, fungi, spores, paleontological specimens, etc.).
1. Product Name: Fully Automatic Low Temperature Sample Processing System
2. Main purpose: Grinding biological samples at low temperature can effectively inhibit nucleic acid degradation, retain protein activity, and process samples in large quantities. It has the functions of tissue homogenization, grinding, cell disruption, homogenization, material dispersion, preparation, and vibration.
Main functions and technical indicators:
Main parameters | Parameter range |
Sample processing: | It can handle 24 samples at the same time in 15 seconds, including liquid nitrogen refrigeration adapters that can be used for 12 and 24 positions |
Compatible sample volume: | 64*(0.2-0.5ML) /64*2ML /12*(5-15)ML /4*15ML /2*25ML /2*50ML, various specifications of grinding tubes can be customized. |
Touch screen display: | Touch screen display, humanized interactive design, convenient operation, convenient and intuitive operation |
Data storage: | Ten groups of experimental data can be stored. According to different experimental samples, animal heart, spleen, lung, kidney, bone, skin, and hair modes are set. |
Mode cycle: | According to the set experimental parameters, it can continuously circulate among several set parameters to further reduce the interference of human factors |
Open cover operation protection: | electromagnetic lock |
Feeding size: | No requirement, adjust according to adapter |
Discharge size: | ~5µm |
The number of grinding platforms (the number of grinding tanks that can be accepted) | >2 |
Fastening device with automatic center positioning | Yes, safety lock during work, full protection. |
Homogenization speed and time: | 0—70 HZ/sec, working time: 0 seconds to 9999 minutes, users can set by themselves; |
Speed range: | 1000rpm-7000rpm |
Diameter of grinding ball: | 0.1-30mm |
Grinding ball material: | alloy steel, chromium steel, zirconia, tungsten carbide, quartz sand; |
Acceleration: | reach a greater speed in 2 seconds |
Deceleration: | reach a lower speed in 2 seconds |
Noise: | <55db |
Refrigeration function: | It has the ability to upgrade to ultra-low temperature liquid nitrogen refrigeration or air refrigerator refrigeration |
Grinding method: | wet grinding, dry grinding and low temperature grinding are all available |
Adapter material: | Adapter material: PTFE or alloy steel |
The adapter can be replaced at will. There are fourteen kinds of adapters to choose from, 0.2ml×96-well plate, 2.0ml×24 adapter, 5.0ml×12 adapter, 15ml×8 adapter, 15ml×8 adapter, 25ml×4 adapter, 50ml ×2 adapter, 2.0ml×48 adapter, 5.0ml×24 adapter, 2.0ml×24 freezing adapter (up to -196 degrees), 5.0ml×12 freezing adapter (up to -196 degrees), 15ml×8 freezing adapter ( Up to -196 degrees), 25ml×2 freezer adapters (up to -196 degrees), 50ml×2 freezer adapters (up to -196 degrees), any specifications can be customized. | |
The supporting centrifuge tube opening tool can quickly assist the staff to open the centrifuge tube and avoid contamination. And equipped with a beading tool. | |
Has a number of patents and provides copies of patent certificates. | |
It is necessary to provide no less than 50 cited papers published on SCI as reference for experimental guidance. | |
Provide not less than 3 years of instrument warranty. | |
The product has an inspection certificate issued by an EU-approved testing organization and meets the three major directives MD2006/42/EC, LVD2014/35/EU, EC2014/30/EU and their standards: EN ISO12100:2010, EN 61010-1:2010, EN 61326-1:2013,EN 61000-3-2:2014, EN 61000-3-3:2013 |