Nitrogen Blowing Apparatus

型号:JXDC-200

品牌:Jingxin

规格:Set

产品简介:JXDC-200 series nitrogen purging instrument is a high-precision temperature control instrument formed by the combination of microcomputer processing and PID control.

product description:

The JXDC-200 series nitrogen purging instrument is a high-precision temperature control instrument formed by the combination of microcomputer processing and PID control. Its working principle is to blow nitrogen to the surface of the heated sample quickly, continuously and controllably, according to the concentration of the solvent. Evaporation speed and boiling point, set heating temperature, realize rapid concentration of a large number of samples.

This instrument uses an aluminum plate heating module, which has good heat transfer and uniform heat transfer, which is conducive to rapid heating and rapid temperature control. Blow nitrogen to the surface of the sample to achieve oxygen-free concentration of the liquid sample. The blowpipes are independent of each other and will not cause cross-contamination. The air needle channels on the air distribution assembly can be used in combination or individually. The system has high temperature control accuracy, wide temperature control range, temperature numerical control digital display, and convenient temperature calibration. The product has beautiful appearance, simple operation, safe and reliable use

The main application areas of this product:

★Analysis of pesticide residues: such as vegetables, fruits, grains, plant tissues

★Environmental analysis: such as drinking water, groundwater and polluted water samples

★Biological analysis: such as sample preparation in hormone analysis, liquid phase, gas phase and mass spectrometry analysis

★Food and beverage: such as milk, wine, beer, etc.

★Pharmaceutical drug testing: such as traditional Chinese medicine, drug screening


Features:

◆The gas needles are independent of each other and will not cause cross-contamination.

◆The flow rate of each gas needle can be adjusted individually

◆The blowpipe channels can be used in combination or individually.

◆Each air needle flow control valve corresponds vertically to the module hole position, and the adjustment is intuitive and convenient.

◆The system has high temperature control accuracy, wide temperature control range, and convenient temperature calibration

◆The lifting components are equipped with independent positioning safety bolts, which are safe for long-term use.


Product parameters:

Main parameters

Parameter range

temperature range

Room temperature+5℃~160℃

Temperature uniformity

±0.5℃

Temperature control accuracy

±0.5℃(@40℃)

Heating time

≤15min(25℃ to160℃)

gas pressure

0.1Mpa

Number of modules

1个

Voltage specifications

220V 50/60Hz

Dimensions

260X220X475(mm)

Timing range

1~99h59min/∞

Display accuracy

0.1℃

Temperature control accuracy

±1℃(@120℃)

Lifting stroke

200mm

Gas flow

15L/min

Air needle length

150mm

power

300W

weight

6.0KG


Optional accessories:

Model

Test tube diameter

Test tube number

MD50

10mm(47mm)Hole depth

12

MD51

12mm(47mm)Hole depth

12

MD52

13mm(47mm)Hole depth

12

MD53

15mm(47mm)Hole depth

12

MD54

16mm(47mm)Hole depth

12

MD55

19mm(47mm)Hole depth

12

MD56

20mm(47mm)Hole depth

12

Custom module

Sample tube specifications provided by the customer

——

相关产品
询价留言
*名称:

单位名称:
*电话:
*联系人:
*城市:
*验证码: